+/* Sysfs conventions report temperatures in millidegrees Celcius.
+ * We could use the low-accuracy two-sample scheme, but can't do the high
+ * accuracy scheme without calibration data. For now we won't try either;
+ * userspace sees raw sensor values, and must scale appropriately.
+ */
+static inline unsigned null_adjust(struct ads7846 *ts, ssize_t v)
+{
+ return v;
+}
+
+SHOW(temp0, temp0, null_adjust) // temp1_input
+SHOW(temp1, temp1, null_adjust) // temp2_input
+
+
+/* sysfs conventions report voltages in millivolts. We can convert voltages
+ * if we know vREF. userspace may need to scale vAUX to match the board's
+ * external resistors; we assume that vBATT only uses the internal ones.
+ */
+static inline unsigned vaux_adjust(struct ads7846 *ts, ssize_t v)
+{
+ unsigned retval = v;
+
+ /* external resistors may scale vAUX into 0..vREF */
+ retval *= vREF_mV;
+ retval = retval >> 12;
+ return retval;
+}
+
+static inline unsigned vbatt_adjust(struct ads7846 *ts, ssize_t v)
+{
+ unsigned retval = vaux_adjust(ts, v);
+
+ /* ads7846 has a resistor ladder to scale this signal down */
+ if (ts->model == 7846)
+ retval *= 4;
+ return retval;
+}
+
+SHOW(in0_input, vaux, vaux_adjust)
+SHOW(in1_input, vbatt, vbatt_adjust)
+