It is unnecessary, to stop queue and turn off carrier in shutdown
routine. With new netdev_queue this causes warnings.
Signed-off-by: Stephen Hemminger <shemminger@vyatta.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
        if (netif_msg_ifdown(sky2))
                printk(KERN_INFO PFX "%s: disabling interface\n", dev->name);
 
-       /* Stop more packets from being queued */
-       netif_stop_queue(dev);
-
        /* Disable port IRQ */
        imask = sky2_read32(hw, B0_IMSK);
        imask &= ~portirq_msk[port];
 
        sky2_phy_power_down(hw, port);
 
-       netif_carrier_off(dev);
-
        /* turn off LED's */
        sky2_write16(hw, B0_Y2LED, LED_STAT_OFF);