- * There is a trick here. We have to read two registers to
- * have the remote sensor temperature, but we have to beware
- * a conversion could occur inbetween the readings. The
- * datasheet says we should either use the one-shot
- * conversion register, which we don't want to do (disables
- * hardware monitoring) or monitor the busy bit, which is
- * impossible (we can't read the values and monitor that bit
- * at the exact same time). So the solution used here is to
- * read the high byte once, then the low byte, then the high
- * byte again. If the new high byte matches the old one,
- * then we have a valid reading. Else we have to read the low
- * byte again, and now we believe we have a correct reading.
- */
- if (lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPH, &oldh) == 0
- && lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPL, &l) == 0
- && lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPH, &newh) == 0
- && (newh == oldh
- || lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPL, &l) == 0))
- data->temp11[0] = (newh << 8) | l;
-
- if (lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &newh) == 0
- && lm90_read_reg(client, LM90_REG_R_REMOTE_LOWL, &l) == 0)
- data->temp11[1] = (newh << 8) | l;
- if (lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &newh) == 0
- && lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHL, &l) == 0)
- data->temp11[2] = (newh << 8) | l;
+ if (data->kind == max6657) {
+ lm90_read16(client, LM90_REG_R_LOCAL_TEMP,
+ MAX6657_REG_R_LOCAL_TEMPL,
+ &data->temp11[4]);
+ } else {
+ if (lm90_read_reg(client, LM90_REG_R_LOCAL_TEMP,
+ &h) == 0)
+ data->temp11[4] = h << 8;
+ }
+ lm90_read16(client, LM90_REG_R_REMOTE_TEMPH,
+ LM90_REG_R_REMOTE_TEMPL, &data->temp11[0]);
+
+ if (lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &h) == 0) {
+ data->temp11[1] = h << 8;
+ if (data->kind != max6657 && data->kind != max6680
+ && lm90_read_reg(client, LM90_REG_R_REMOTE_LOWL,
+ &l) == 0)
+ data->temp11[1] |= l;
+ }
+ if (lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &h) == 0) {
+ data->temp11[2] = h << 8;
+ if (data->kind != max6657 && data->kind != max6680
+ && lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHL,
+ &l) == 0)
+ data->temp11[2] |= l;
+ }
+