temp5-6 have a 1 degree Celsiis resolution.
* Temperature sensor types
- Temp1-4 have 3 possible types. It can be read from (and written to)
+ Temp1-4 have 2 possible types. It can be read from (and written to)
temp[1-4]_type.
- - If the value of 0, the related temperature channel stops
- monitoring.
- If the value is 3, it starts monitoring using a remote termal diode
(default).
- - If the value is 5, it starts monitoring using the temperature sensor
- in AMD CPU and get result by AMDSI.
- If the value is 6, it starts monitoring using the temperature sensor
in Intel CPU and get result by PECI.
Temp5-6 can be connected to external thermistors (value of
- temp[5-6]_type is 4). They can also be disabled (value is 0).
+ temp[5-6]_type is 4).
* Alarm mechanism
For voltage sensors, an alarm triggers if the measured value is below