Reset the event type after encoding a system message to prevent any
following data bytes from being interpreted as data for a running status
system message, which is not allowed in MIDI.
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Jaroslav Kysela <perex@suse.cz>
                ev->flags |= SNDRV_SEQ_EVENT_LENGTH_FIXED;
                if (status_event[dev->type].encode) /* set data values */
                        status_event[dev->type].encode(dev, ev);
+               if (dev->type >= ST_SPECIAL)
+                       dev->type = ST_INVALID;
                rc = 1;
        } else  if (dev->type == ST_SYSEX) {
                if (c == MIDI_CMD_COMMON_SYSEX_END ||