On digsy MTC PSC4 and PSC5 should be configured as UART, not PSC3 and PSC4.
Signed-off-by: Grzegorz Bernacki <gjb@semihalf.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
                        reg = <0x1f00 0x100>;
                };
 
-               serial@2400 {           // PSC3
-                       compatible = "fsl,mpc5200b-psc-uart","fsl,mpc5200-psc-uart";
-                       reg = <0x2400 0x100>;
-                       interrupts = <2 3 0>;
-               };
-
                serial@2600 {           // PSC4
                        compatible = "fsl,mpc5200b-psc-uart","fsl,mpc5200-psc-uart";
                        reg = <0x2600 0x100>;
                        interrupts = <2 11 0>;
                };
 
+               serial@2800 {           // PSC5
+                       compatible = "fsl,mpc5200b-psc-uart","fsl,mpc5200-psc-uart";
+                       reg = <0x2800 0x100>;
+                       interrupts = <2 12 0>;
+               };
+
                ethernet@3000 {
                        compatible = "fsl,mpc5200b-fec","fsl,mpc5200-fec";
                        reg = <0x3000 0x400>;